"Inverter address"
The value entered is the identification number (Unit ID) assigned to the inverter. Can be
found on the user interface of the inverter in the Communication - Modbus menu.
Factory setting: This value is invariably defined as 1.
Inverter control via Modbus
If this option is activated, the inverter is controlled via Modbus.
Inverter control includes the following functions:
- On/Off
- Power reduction
- Specification of a constant power factor (cos phi)
- Specification of a constant reactive power value
- Battery control specifications with battery
Fronius Solar API The Fronius Solar API is an Ethernet-based, open JSON interface. When enabled, IOT
devices on the local network can access inverter information without authentication. For
security reasons, the interface is deactivated at the factory and should not be activated if
it is not required for a third-party application (e.g. EV charger, smart home solutions,
etc.).
For monitoring, Fronius recommends using Fronius Solar.web instead, which provides
secure access to inverter status and production information.
When performing a firmware update to version 1.14.x, the setting (activated/deactivated)
of the Fronius Solar API is adopted.