EasyManua.ls Logo

Fronius Symo GEN24 6.0.Plus

Fronius Symo GEN24 6.0.Plus
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fronius Symo
GEN24 8.0 / 8.0
Plus
DC input data
MPP voltage range
(at rated power)
224 - 800 V
Max. connected load (P
PV max
)
Total
PV 1
PV 2
12000 Wp
10000 Wp
7000 Wp
Max. processable PV power
Total
PV 1
PV 2
8260 Wp
8260 Wp
6000 Wp
Max. input voltage
at 1000 W/m² / -10 °C in an open circuit
1000 V
Feed-in start-up input voltage in grid oper-
ation
5)
80 V
Max. input current
PV 1
PV 2
25.0 A
12.5 A
Max. short circuit current of solar modules
(I
SC PV
)
PV 1
PV 2
37.5 A
18.75 A
Max. short circuit current
(I
SC PV1
+ I
SC PV2
= I
SC max
)
Total
56.25 A
Max. inverter backfeed current to the ar-
ray
3)
37.5 A
Number of inputs - PV 1 2
Number of inputs - PV 2 1
Max. capacity of the PV generator against
earth
1600 nF
DC input data battery
8)
Max. voltage 531 V / 700 V *
* only with suitable disconnection device
between inverter and battery in the event
of a fault
Min. voltage 160 V
Max. current 22 A
Max. output 8000 W
DC inputs 1
AC input/output data
Rated power (P
nom
) 8000 W
Max. output power 8000 W
Rated apparent power 8000 W
146

Table of Contents

Related product manuals