EasyManua.ls Logo

Fronius Symo GEN24 6.0.Plus

Fronius Symo GEN24 6.0.Plus
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fronius Symo GEN24
Device concept The inverter transforms the direct current generated by the PV modules into alternating
current. This alternating current is fed into the public grid and synchronized with the
mains voltage in use. Moreover, the solar energy can also be stored in a connected bat-
tery for later use.
The inverter is intended for use in grid-connected photovoltaic systems. The inverter has
backup power functions and switches to backup power mode if it has been wired accord-
ingly*.
The inverter automatically monitors the public grid. Whenever conditions in the electric
grid are inconsistent with standard conditions (for example, grid switch-off, interruption),
the inverter will immediately stop producing power and interrupt the supply of power into
the grid.
The grid is monitored by monitoring the voltage, frequency and islanding conditions.
After installation and commissioning, the inverter's operation is fully automatic;
the inverter draws the maximum possible power from the PV modules.
Depending on the operating point, this power is used in the home, stored in a battery* or
fed into the grid.
As soon as the energy provided by the PV modules is no longer sufficient, the power
from the battery is fed into the home. Depending on the setting, power may also be ob-
tained from the public grid in order to charge the battery*.
When its temperature gets too high, the inverter automatically reduces the output or
charging power, or switches off completely, in order to protect itself.
Reasons for the temperature being too high include a high ambient temperature or insuf-
ficient heat dissipation (for example, inadequate heat dissipation when installed in switch
cabinets).
* Depending on the device variant, suitable battery, appropriate wiring, settings
and local standards and guidelines.
Function over-
view
Function Symo GEN24 Symo GEN24 Plus
Backup power variant - PV Point (OP)
Battery connection*
Available as an op-
tion**
Backup power variant - Full Backup
Available as an op-
tion**
* For suitable batteries, see chapter Suitable battery.
** The functions are optionally available via Fronius UP (see chapter Fronius UP).
Fronius UP With Fronius UP*, the inverter can be expanded by the authorised specialist to include
optionally available functions (see chapter Function overview).
* The availability of Fronius UP varies from country to country. For more informa-
tion on Fronius UP and availability, see Installation guide: Fronius GEN24 &
GEN24 Plus.