feed-in point for Full Backup backup power mode.
IMPORTANT!
When configuring "PV Point" backup power mode, the information in chapter Safety on
page 73 must be observed.
When configuring "Full Backup" backup power mode, the information in chapter Safety
on page 78 must be observed.
Backup power nominal voltage
When backup power mode is activated, the nominal voltage of the public grid must be
selected.
State of charge warning limit
A warning is output when the residual capacity of the battery specified here is reached in
backup power mode.
Reserve capacity
The set value results in a residual capacity (depending on the capacity of the battery)
that is reserved for backup power. The battery is not discharged below the residual capa-
city in grid-connected operation. In backup power mode, the manually set value "Minim-
um SoC" is not taken into account. If there is a power outage, the battery is always dis-
charged down to the automatically preset minimum SoC in accordance with the technical
specifications of the battery manufacturer.
Load management
Up to four pins can be selected for load management here. Additional load management
settings are available in the "Load management" menu item.
Default: Pin 1
Australia - Demand Response Mode (DRM)
The pins for control via DRM can be set here:
Mode Description Information DRM pin I/O pin
DRM0 Inverter disconnects it-
self from the grid
DRM0 occurs if there is an
interruption or short circuit
on the REF GEN or COM
LOAD leads, or if the com-
binations DRM1 - DRM8
are invalid.
The mains relays open.
REF GEN
COM
LOAD
IO4
IO5
DRM1 Import P
nom
≤ 0%
without disconnection
from the grid
currently not supported DRM 1/5 IN6
DRM2 Import P
nom
≤ 50% currently not supported DRM 2/6 IN7
DRM3 Import P
nom
≤ 75% &
+Q
rel
* ≥ 0%
currently not supported DRM 3/7 IN8
DRM4 Import P
nom
≤ 100% currently not supported DRM 4/8 IN9
DRM5 Export P
nom
≤ 0%
without disconnection
from the grid
currently not supported DRM 1/5 IN6
DRM6 Export P
nom
≤ 50% currently not supported DRM 2/6 IN7
DRM7 Export P
nom
≤ 75% &
-Q
rel
* ≥ 0%
currently not supported DRM 3/7 IN8
DRM8 Export P
nom
≤ 100% currently not supported DRM 4/8 IN9
97
EN