54
Troubleshooting
Safety
WARNING!
Risk of electric shock.
This can result in serious injury and damage to property. Before opening the device:
Turn the power source mains switch to the "O" position
Disconnect the power source from the mains
Attach a clearly legible and easy-to-understand warning sign to prevent anyone switch-
ing it on again
After opening the device, discharge any live components (e.g. capacitors).
Other faults
Power source does not function
Mains switch is ON, but indicators are not lit up
Cause: there is a fault in the mains lead; the mains plug is not plugged in
Remedy: check mains lead, check mains voltage if necessary
Cause: mains fuse is faulty
Remedy: replace mains fuse
Cause: mains outlet socket or plug is faulty
Remedy: replace faulty components
Cause: mains switch is faulty
Remedy: replace mains switch
Cause: phase conductors (L1, L2, L3) connected incorrectly
Remedy: connect phase conductors as described
Mains fuse or automatic circuit breaker has tripped
Cause: Mains fuse underrated
Remedy: Rate mains lead fuse according to rating plate
Cause: Short circuit on the transformer windings
Remedy: Replace the auto-transformer
Cause: Auto-transformer not connected correctly
Remedy: Correct the mains connection
Output voltage too low
Cause: Incorrect mains voltage
Remedy: Check the mains voltage
Cause: Mains leads are connected incorrectly
Remedy: Correct mains connection
Cause: L1/L2/L3 swapped with N-conductor
Remedy: Correct the mains connection