56
Technical data
General remarks IMPORTANT! If the auto-transformer is designed for special voltages, the technical data
on the rating plate apply. The mains plug, mains lead, and their fuses must be dimensioned
accordingly.
Auto-transformer
TPS 2700, Auto-
transformer TPS
5000
Auto-transformer
TIME 5000
Auto-transformer
TPS 2700
Auto-transformer
TPS 5000
Mains voltage 1 (+/- 10 %) 3 x 500 V 3 x 500 V
Mains voltage 2 (+/- 10 %) 3 x 480 V 3 x 480 V
Output voltage 3 x 400 V 3 x 400 V
Mains fuse protection (slow-blow) 16 A 32 A
Maximum apparent power 9,7 kVA 27,6 kVA
Effective apparent power 5,5 kVA 20,7 kVA
Cos phi 0,9 0,9
Maximum primary current at
mains voltage 1 (500 V)
mains voltage2 (480 V)
11 A
12 A
32 A
34 A
Effective primary current at
mains voltage 1 (500 V)
mains voltage2 (480 V)
6,5 A
7,0 A
24 A
25 A
Secondary current at
10 min / 40 °C 40 % d.c.
10 min / 40 °C 100 % d.c.
15 A
8 A
40 A
30 A
Protection IP 23 IP 23
Type of cooling F F
Insulation class F F
Dimensions l/w/h 640/290/230 mm
25.2/11.42/9.06 in.
650/290/230 mm
25.59/11.42/9.06 in.
Weight 23 kg
50.71 Ib.
41 kg
90.39 Ib.
Marks of conformity CE CE,
Auto-transformer
TIME 5000
Mains voltage 1 (+/- 10 %) 3 x 500 V
Mains voltage 2 (+/- 10 %) 3 x 480 V
Output voltage 3 x 400 V
Mains fuse protection (slow-blow) 40 A
Maximum apparent power 33,3 kVA
Effective apparent power 22,2 kVA
Cos phi 0,9