Service messag-
es
If "Err" is displayed on the left display and an error code is displayed on the right display,
this is an internal service code for the power source.
Example:
There can be multiple error codes. These appear by turning the selection dial.
Take note of all displayed error codes as well as the serial number and configuration of the
power source, and then contact the service center with a detailed error description.
Err | 1-3 / 11 / 15 / 21 / 33-35 / 37-40 / 42-44 / 46-52
Cause: Power module error
Remedy: Contact the service team
Err | 4
Cause: Open circuit voltage has not been reached:
Electrode is in contact with the component/hardware defect
Remedy: Remove the electrode support from the component. If the service code con-
tinues to be displayed, contact service team
Err | 5 / 6 / 12 / 14
Cause: System start failure
Remedy: Turn device off and on again. If this happens multiple times, inform service
team
Err | 10
Cause: Overvoltage at the current socket (> 113 V
DC
)
Remedy: Contact the service team
Err | 16 / 17 / 18
Cause: Memory error
Remedy: Contact service team
;
Err 16: press selection dial to acknowledge service message
NOTE!
For standard device variants, acknowledging the service message does not have an
effect on the power source's range of functions.
For all other device variants (TIG, etc.), the power source only offers a restricted range of
functions after acknowledgment. Inform the service team to re-establish the full range of
functions.

Table of Contents

Other manuals for Fronius TransTig 170

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 170 and is the answer not in the manual?

Fronius TransTig 170 Specifications

General IconGeneral
BrandFronius
ModelTransTig 170
CategoryWelding System
LanguageEnglish

Related product manuals