91
EN
Err | 052
Cause: Mains overvoltage: The mains voltage has exceeded the upper limit of the tol-
erance range (see section "Technical data")
Remedy: Check the mains voltage
no | IGn
Cause: "Ignition time-out" function is active; current did not start flowing before the
length of wire specified in the set-up menu had been fed. The power source
safety cut-out has tripped.
Remedy: Press the torch trigger repeatedly; clean the workpiece surface; if necessary,
increase the time until the safety cut-out is triggered in the set-up menu: level
2
Err | PE
Cause: The earth current watchdog has triggered the safety cut-out of the power
source.
Remedy: Switch off the power source, wait for 10 seconds and then switch it on again.
If you have tried this several times and the error keeps recurring, contact Af-
ter-Sales Service.
Err | IP
Cause: Primary overcurrent
Remedy: Contact After-Sales Service
Err | bPS
Cause: Fault in power module
Remedy: Contact After-Sales Service
dSP | Axx
Cause: Fault in the central control and regulation unit
Remedy: Contact After-Sales Service
dSP | Cxx
Cause: Fault in the central control and regulation unit
Remedy: Contact After-Sales Service
dSP | Exx
Cause: Fault in the central control and regulation unit
Remedy: Contact After-Sales Service
dSP | Sy
Cause: Fault in the central control and regulation unit
Remedy: Contact After-Sales Service
dSP | nSy
Cause: Fault in the central control and regulation unit
Remedy: Contact After-Sales Service
no | Arc
Cause: Arc break
Remedy: Press the torch trigger repeatedly; clean the surface of the workpiece
no | H2O
Cause: Cooling unit flow watchdog has been triggered
Remedy: Check the cooling unit; if necessary, top up the coolant or bleed the system
as described in "Putting the cooling unit into service"

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 4000 and is the answer not in the manual?

Fronius TransTig 4000 Specifications

General IconGeneral
BrandFronius
ModelTransTig 4000
CategoryWelding System
LanguageEnglish

Related product manuals