ii
DANGER
Adequate means must be provided to limit the movement of this appliance without depending
on or transmitting stress to the electrical conduit. A restraint kit is provided with the fryer. If
the restraint kit is missing contact your local KES.
DANGER
Prior to movement, testing, maintenance and any repair on your Frymaster fryer, disconnect all
electrical power from the fryer.
ELECTRICAL POWER SPECIFICATIONS
Three (3) Phase Requirements
kW
V
OLTAGE PHASE
WIRE
SERVICE
MINIMUM SIZE AMPS PER LEG
AWG mm
2
L1 L2 L3
14 208 3 3 6 16 39 39 39
14 240 3 3 6 16 34 34 34
14 480 3 3 8 10 17 17 17
14 220/380 3 4 6 16 21 21 21
14 240/415 3 4 6 16 20 20 21
14 230/400 3 4 6 16 21 21 21
17 208 3 3 6 16 48 48 48
17 240 3 3 6 16 41 41 41
17 480 3 3 6 16 21 21 21
17 220/380 3 4 6 16 26 26 26
17 240/415 3 4 6 16 24 24 24
17 230/400 3 4 6 16 25 25 25