2 Installation and Connection 2-1
FVR-C11S-EN
2
2 Installation and Connection
Table 2-1-1 Operatin
g
environment
2-1 Operatin
g
Environment
Install this product at a place satisf
y
in
g
the conditions listed in
Table 2-1-1.
Item Specifications
Place Indoor
Ambient temperature -10 to +50 °C
Ambient relative humidit
y
5 to 95%RH (No condensation allowed)
Atmosphere The product must not be exposed to dust, direct sunli
g
ht, corrosive
g
as, inflammable
g
as, oil mist, vapor, or water drops.
There must be no salt in the atmosphere. Condensation must not
be caused b
y
sudden chan
g
es in temperature.
Altitude 1000 m or less (Air pressure : 86kPa to 106kPa)
Vibration 3mm: 2 ~ 9 Hz or less
9.8 m/s
2
: 9 ~ 20 Hz or less
2 m/s
2
: 20 ~ 55 Hz or less
1 m/s
2
: 55 ~ 200 Hz or less

Table of Contents