FVR-C11S-EN
5-8 5 Selectin
Function
5
Chan
e durin
operation: X = impossible, = possible (enabled b
usin
), = possible (enabled b
usin
)
External si
nal operation (Di
ital input)
(FWD, REV)
When the external power suppl
is
used (Set SW7 at CM):
Forward operation with +24 to +27 VDC
supplied to FWD - P24/CM and decel-
eration to stop with them open.
Reverse operation with +24 to +27 VDC
supplied to REV - P24/CM and deceler-
ation to stop with them open.
No operation with +24 to +27 VDC
supplied to both FWD - P24/CM and
REV - P24/CM.
When the internal power suppl
is used
(Set SW7 at P24):
Forward operation with FWD - P24/CM
short-circuited and deceleration to stop
with them open.
Reverse operation with REV - P24/CM
short-circuited and deceleration to stop
with them open.
No operation with both FWD - CM and
REV - CM short-circuited.
Ke
pad operation
(forward rotation) [ ke
]
The motor runs forward when the
ke
is pressed and decelerates-
to-stop when the ke
is pressed.
FWD and REV terminal input is i
-
nored.
Ke
pad operation
(reverse rotation) [ ke
]
The motor runs in reverse when the
ke
is pressed and decelerates-
to-stop when the ke
is pressed.
FWD and REV terminal input is i
-
nored.
Note: This function can be chan
ed onl
while the FWD and REV terminals
are open.
Maximum output frequenc
This function sets the maximum output frequen-
c
.
1
2
3
Factor
settin
Chan
e durin
operation
50Hz X
The maximum output frequenc
can be set with a resolution of 1 Hz
in a ran
e between 50 and 120 Hz.
to
F03
50
120
f
V
Maximum volta
e
Maximum
output frequenc
CAUTION
Hi
h-speed operation can be set b
the inverter easil
. Carefull
check the
limit of the motor and machine before
chan
in
the settin
.
Otherwise in
uries could occur.