9 Specifications 9-5
FVR-C11S-EN
9
Item Specifications Remarks
Indication
Tripped
[Cause of trip b
code]
z
OC1 (Overcurrent: durin
acceleration)
z
OC2 (Overcurrent: durin
deceleration)
z
OC3
(Overcurrent: while runnin
at constant speed)
z
OU1 (Overvolta
e: durin
acceleration)
z
OU2 (Overvolta
e: durin
deceleration)
z
OU3
(Overvolta
e: while runnin
at constant speed)
z
LU (Undervolta
e)
z
OH1 (Overheatin
: Heat sink)
z
OH2 (Overheatin
: External alarm)
z
OL (Overload: Motor)
z
OLU (Overload: Inverter)
z
Er1 (Memor
error)
z
Er3 (CPU error)
z
Er8 (RS485 communication error)
z
Lin (Input phase failure)
Runnin
, Tripped
z
Fault histor
data is stored and indicated for the
past four trips. Data is retained while power is off.
Protection
Overload
z
Internal electronic thermal overload rela
protects
inverter overload.
Overvolta
e
z
Detect the excessive DC link circuit volta
e to stop
inverter.
Overcurrent
z
Detect overcurrent due to overload on inverter out-
put side to protect inverter
Incomin
sur
e
z
Detect incomin
sur
e volta
e between AC power
and the earth to protect inverter.
Undervolta
e
z
Detect the DC link circuit undervolta
e to stop in-
verter
Overheatin
z
Detects the coolin
fan fault or abnormal tempera-
ture rise of inverter to protect inverter.
Short-circuit
z
Detect overcurrent due to short-circuit on inverter
output side to protect inverter.