EasyManua.ls Logo

Fujitsu 5GRUDB3 - Page 73

Fujitsu 5GRUDB3
111 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Dynamic Range
Table 27
Total Power Dynamic Range (15 kHz SCS)
Base Station Channel Bandwidth (MHz) Total Power Dynamic Range Test Tolerance
5 ≥ 13.9 dB 0.4dB
10 ≥ 17.1 dB
15
1
≥ 18.9 dB
20 ≥ 20.2 dB
1
15 MHz is not currently supported.
Table 28
RE (Resource Element) Power Control Dynamic Range
Modulation Scheme Used On e RE
RE Power Control Dynamic Range
Down Up
QPSK Physical Downlink Control Channel
(PDCCH)
–6 dB +4 dB
QPSK (PDSCH) –6 dB +3 dB
16QAM PDSCH –3 dB +3 dB
64QAM PDSCH 0 dB 0 dB
256QAM PDSCH 0 dB 0 dB
Note: Total TX power is always less or equal to maximum base station output power.
FCC Out-of-Band Emission Specication
FCC rule
CFR 47 § 27.53, CFR 47 § 27.1134 for n70, n66
−19 dBm/RBW per port [= −13 dBm/single-transmit −6 dB (10 x log (4, No. of TX)].
Resolution Bandwidth for Frequency (RBW)
>1 MHz bands immediately outside and adjacent to the frequency block have the following specications:
n70 200 kHz (Max)
n66 200 kHz (Max)
Outside 1 MHz, the reference bandwidth (1 MHz) is applied.
RU Hardware Feature
Performance Requirement
73
Release 1.0 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only