Connection configuration between
Contr
oller 0 and the I/O module line 0
Connection configuration between
Controller 1 and the I/O module line 1
Controller enclosure
Drive enclosure 1
Drive enclosure 2
(drive enclosure
that is to be added)
Controller 0 Controller 1
Remove
fr
om here
Connect here
Connect here
Remove
from here
Connect here
Connect here
Connect here
Connect here
1 In the [Storage] screen of [Component] on the ETERNUS Web GUI screen, check that all components of
the ETERNUS AF are in normal status. In addition, check the DE-IDs (drive enclosure numbers) of the
installed enclosures in the [Drive Enclosure] screen.
2 Display the [Add Drive Enclosure] screen.
(1) In the [Storage] screen of [Component], click [Add Drive Enclosure] in [Action].
The [Add Drive Enclosure] screen appears.
4. Component Expansion/Function Enhancement
Installing Additional Drive Enclosures
37 Operation Guide (Basic)