ETERNUS DX500 S3/DX600 S3 Components (Rear)
This section describes the controllers and the power supply units in the rear of the controller enclosure.
■
Controller
The controller contains a CPU,
cache memory, host interfaces, Bootup and Utility Device (BUD), and drive inter-
face (DI) ports. The controller controls all operations in the ETERNUS DX.
● Controller (ETERNUS DX500 S3)
Figure 17 shows the controller of the ETERNUS DX500 S3.
Figure 17 Controller (ETERNUS DX500 S3)
1. Host interface (CA#0)
Install host interfaces.
2. Host interface (CA#1)
Install host interfaces.
3. FST (LAN) port
A port that is dedicated for maintenance engineers. Customers must not use this port.
4. RMT (LAN) port
This port is used for connecting a LAN cable and used for the remote support function. This port uses an RJ-45
connector.
5. MNT (LAN) port
This port is used for connecting a LAN cable and used for operation management. This port uses an RJ-45 con-
nector.
6. DI (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a mini SAS HD cable between enclo-
sures.
7. PWC port
This port is used to connect a power synchronized unit with an RS232C cable.
1. Component Names and LED Names
Controller Enclosures
23
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems
Operation Guide (Basic)
Copyright 2018 FUJITSU LIMITED
P3AM-7742-12ENZ0