52 Operating Manual TX200 S5
Installing/removing the rack model Installing the hardware
Racks with installation depth smaller/greater than 735 mm
The support systems can be used for installation depths of 714 - 785 mm. The
spring element of the support system is used to adjust the length as required.
Ê Secure the support systems as described in “Installing the support systems”
on page 48.
Ê Mount the server (see “Inserting the server” on page 50) and route the
cables as described in the original manual of the rack..
V CAUTION!
Ensure that the safety lock has been inserted before the server is
inserted (see figure 5 on page 48).