90 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1121 February 2016
setnameserver
(8) command
For the domainname operand, description is updated as follows:
Specifies the domain name of the DNS search path to be
registered or deleted. You can specify up to five domain names,
each separated by a space. domainname is specified in up to 254
characters with label elements delimited by a "." (period). If a
domain name exceeding 254 characters is specified, an error
occurs. The label element of the domain name can contain letters
(a to z, A to Z), numbers (0 to 9), and the special characters "-"
(hyphens) and "." (period). The domain name must begin with a
letter and end with either a letter or number. A "." (period) can
be used as delimiter.
SPARC Enterprise
M3000/M4000/M5000/
M8000/M9000 Servers
XSCF Reference Manual
setntp(8),
showntp(8)
command
For the address operand, a part of description is updated as
follows:
A host name is specified in up to 64 characters with label
elements delimited by a "." (period). The label element of the
host name can contain letters (a to z, A to Z), numbers (0 to 9),
and the special characters "-" (hyphens) and "." (period). The host
name must begin with a letter and end with either a letter or
number. A "." (period) can be used as delimiter. Host name, if
specified, must be resolvable.
setpasswordpo
licy(8)
command
The following description for the initial setting of -m minlen will
be added:
The initial setting is 9.
setupfru(8)
command
The following description also applies to M4000/M5000 servers:
Although a CMU with two CPUs can be configured into Quad-
XSB mode on an M8000/M9000 server, the server generates a
"configuration error" message for those XSBs that do not have a
CPU and memory.
showhardconf
(8) command
In DESCRIPTION, "External I/O Expansion Unit information"
and "PCI card information" are added with the following note:
(displayed only while the domain power is on)