Chapter 6 Information About Hardware of M8000/M9000 Servers 119
For notes on hardware RAID, see “Notes on Hardware RAID” on page 114.
Hardware Documentation Updates
This section contains late-breaking hardware information that became known after
the documentation set was published and corrections in the M8000/M9000 servers
hardware documentation.
TABLE 6-3 lists known documentation updates.
ESF (Enhanced Support
Facility)/Supported Oracle
Solaris OS/Required patches
3.0 or later Oracle Solaris 10 914527-17
4.0 Oracle Solaris 11 T006481SP-01
XSCF firmware XCP 1110 or later
RAID level • RAID 1 (IM: Integrated Mirror) only
• Two member disks can be configured per RAID volume
Disk drive • The member disks in a single RAID volume shall be made up of disk drives
of the same capacity and of the same rotational speed
• Solid State Drive (SSD) is not supported
Number of RAID volumes Up to one RAID volume per a RAID-capable IOUA
* To obtain SUNWigb package, contact your sales representative.
TABLE 6-2 Requirements for Hardware RAID Support (Continued)
Item Description