48 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1121 February 2016
RTIF1-
101029-001
O When you use the setroute(8)
command to set the gateway address
and if you mistake the setting or the
gateway has been stopped, XSCF
hangs up.
To set the gateway address, confirm
that the specified address is correct.
Before resetting XSCF by using the
rebootxscf(8) command, confirm
that the gateway is operating
properly.
RTIF1-
101102-001
O When the RCI of XSCF#0 and XSCF#1
both got the communication error, the
RCI asynchronous monitoring of
PRIMECLUSTER does not stop
normally but gets the monitoring
timeout, which delays the switching
of the clusters after the error detected.
No workaround is available.
RTIF1-
101215-001
OOOWhile XSCF is running, a process may
go down. After this, XSCF may reset.
No workaround is available.
This error log can be safely ignored.
RTIF1-
110216-001
O When you execute the
showenvironment power command
on the M3000 server with SPARC64
VII+ processors, an incorrect value of
"Permitted AC power consumption"
will be displayed with 470 W.
No workaround is available.
The correct value is 505 W for AC
power supply model and is 510 W for
DC power supply model.
RTIF1-
110222-002
OOOXSCF sends Rst packets without AH
header when dscp disconnects,
resulting in false security
vulnerability alarms.
The domain console may display this
message:
ipsec_check_inbound_policy:
Policy Failure for the incoming
packet (not secure).
This message can be safely ignored.
RTIF1-
110523-001
OOOFrom the OpenBoot PROM prompt
(ok), when you use the nvalias
command and try setting a devalias
to the environmental variable
nvramrc, it may fail with the message
"Can't create new alias
because nvramrc is full."
In case this event occurred, redo the
settings of any devalias which is
already defined in the environmental
variable nvramrc, by using the
nvalias command. Then, in order to
set the failed devalias, execute the
nvalias command once again.
RTIF1-
110526-001
OOOInvoking ' setsnmp' without options
results in segmentation fault.
To view 'setsnmp' usage options, use
'setsnmp -h'
TABLE 3-3 XCP Issues Fixed in Releases Earlier Than XCP 1121 (Continued)
ID M3000
M4000
M5000
M8000
M9000 Description Workaround