5-2
2. Daily Test
2.1 Procedures
1. Press [3/TEST/DEF] key on DSC stanby screen or Radiotelephone setting screen.
2. The test automatically starts. No canceling during self-test.
3. It takes 30 to 40 seconds to finish the test. Then, the distress signal receiving alarm LED flashes, and
the buzzer and external speaker sound.
4. The test results are displayed.
If a printer is connected, the test results can be printed out by pressing [8/PRINT/TUV] key.
Note)
The default setting of DAILY TEST in PRINT OUT submenu of “Setup menu” is “MANUAL”. To
print out the test results automatically, set it at “AUTO”. The printed date and time is the NMEA data
(ZDA) from the navaids.
Test result printed out
5. Pressing [CANCEL] key. Then, the screen returns to the standby screen.
2. Daily Test
WATCH KEEPING
DISTRESS
ROUTINE
AUTO ACK
VOLUME
2187.5 4207.5 6312.0
16804.5 12577.0 8414.5
2177.0 4219.5 6331.0
16903.0 12657.0 8436.5
32
45 00.000N 135 00.000E 23:59
VOLUME 32
TX : 12 329.0 kHz
RX : 13 17600 kHz
POWER : HIGH
TUNE : NO TUNE
MODE : TELEPHONE
CH:12034
or
DSC standby screen RT setting screen
* * Complete test * *
MAIN CPU
MODEM
RCVR1
RCVR2
REMOTE RT
REMOTE DP
: OK VER.xx
: OK VER.xx
: OK
: OK
: OK FS-1562
: OK DP-6
* * Complete test * *
MAIN CPU
MODEM
RCVR1
RCVR2
REMOTE RT
REMOTE DP
: OK VER.xx
: OK VER.xx
: OK
: OK
: OK FS-1562
: OK DP-6
MMSI
: 123456789
JAN - 10 - 2000 - 15:26
* * Complete test * *
MAIN CPU
MODEM
RCVR1
RCVR2
REMOTE RT
REMOTE DP
:
:
:
:
:
: