6-3
2. Measurements
2.2 Frequency and power measurement
The units are connected as below to measure the frequnecy and power of the output signal.
Measurement of output power from the main unitMeasurement of output power from the main unit
Measurement of output power from the main unitMeasurement of output power from the main unit
Measurement of output power from the main unit
Measurement of antenna power using dummy loadMeasurement of antenna power using dummy load
Measurement of antenna power using dummy loadMeasurement of antenna power using dummy load
Measurement of antenna power using dummy load
DSC-60 FS-xxxx
HANDSET
Setting freq. and F1B(J2B) mode
Freq. counter
Pick-up
Dummy
50 ohms(Power meter)
RT
DSC-60 FS-xxxx
HANDSET
Setting freq and F1B(J2B) mode
AT-xxxx
Freq. counter
Pick-up
Dummy
10 ohms + 250pF 50 ohms(power meter)
MF BAND HF BAND