4-14
2.9 System setup
This protected setting or to open the menu requires password entry.
Pressing [#/SETUP] key reveals “Setup menu” screen. Select SYSTEM, and press [ENT] key. Then,
the following “System setup” screen appears.
Note) How to cancel the protection
Enter “ ” from the numeric keys. Then, “PROTECTION ON” is changed to
“PROTECTION OFF”, which enables setting of each item.
1. MMSI
The registered MMSI Number is reading only, that is, can not be changed in this menu.
2. WATCH RCVR (Default setting: MF/HF)
This item sets the frequencies of DSC watch keeping receiver.
- MF/HF : Up to 6 scan frequencies can be selected for the receiver of MF/HF DSC mes-
sages. Refer to Page 4-11 for the method of setting the scan frequencies.
- MF : The receiver frequency is fixed to 2187.5 kHz.
ON
OFF
OFF
ON
* * System setup * *
: ON
MMSI
WATCH RCVR
LINE OUT LEVEL
TX-KEY TIMING
RT PORT
: 123456789 FIXED
: MF/HF
: +0dBm
: AUTO
: MIF
PROTECTION
REMOTE STATION
NBDP PORT
LANGUAGE
: ON
: OFF
: ENGLISH
* * System setup * *
: ONPROTECTION
LEVEL(-12
+12)DBM
00
TIME(AUTO
15)SEC
AUTO
MF/HF
MF
MIF
IEC
OFF
2. System setup(System setup)