Page 82
22) Press No. The display will show:-
23) Press Yes. The display will show:-
Note: Zone Response time is defaulted to 400ms and may not
be changed.
24) Press Yes. The display will show:-
Note: Fault /Mask response time may be programmed as a
global parameter and may be reprogrammed from 2 to 14
seconds. (increments of 2 seconds).
The time programmed for this option will apply to all zones, there is no option for individual response
times per zone. It is a global setting.
Once the Fault / Mask as been triggered the response time for the Fault / Mask will revert to the
default time of 400ms until the fault / mask problem has cleared.
25) Press No until the settings you require are
displayed. Then press Yes. The display will show:-
Wiring Modes available are
:-
16(2 Wire) Two wires are used for the zone and a global tamper is used.
(Version / Grade dependant - Cannot be used in Grade 3
installations).
8(4 Wire). May be programmed for 8 four wire zones. Wire 8 individual zones
with their own tampers.
16(EOL) Two wires are used in conjunction with two resistors to give
End Of Line wiring, this is the most secure wiring format.
Note: This tutorial assumes that 16(EOL) has been selected
.
26) With the display showing:-
Press Yes.
27) The display will show:-
Program Zone
Wiring ?
On-Board Zones
=16 <EOL>
Zone Response
:400 mS
Fault / Mask Zones
Response=Norm
On-Board Zones
=16 <EOL>
On-Board EOL
=Norm
PR5892 Rev11 800 Series Eng Ref 15.qxd 16/11/2006 11:21 Page 82