EasyManua.ls Logo

GE Innova 3100 User Manual

GE Innova 3100
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GE Healthcare
Innova 2100-IQ, 3100/3100-IQ, 4100/4100-IQ
Cardiovascular Imaging System
Pre-Installation Manual
OPERATING DOCUMENTATION
5160944-13-1EN
Revision 2

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the GE Innova 3100 and is the answer not in the manual?

GE Innova 3100 Specifications

General IconGeneral
Frame RateUp to 30 fps
Generator Power100 kW
Detector TypeFlat Panel Detector
Detector Size31 cm x 31 cm
Voltage Range40 to 125 kV
Current Range10 - 1000 mA
Image ProcessingAdvanced Image Processing Software
System WeightApproximately 2500 kg
Power Requirements50/60 Hz
ApplicationCardiovascular, Angiography, Interventional Radiology
Display MonitorsDual high-resolution monitors

Summary

Chapter 1 Introduction

2 Responsibilities of the Purchaser/Customer

Outlines the duties of the purchaser/customer during installation.

3 Pre-Installation Process

Details the steps and checklists for preparing the site before installation.

Chapter 2 Innova Systems

3 Basic Innova System Compatibility

Chapter 3 Physical Requirements of Room

2 Environmental Requirements/Limitations

Specifies environmental conditions and limitations for system operation.

2.1 Room Climate

Details the required room climate, including humidity and temperature.

2.2 Equipment Heat Output (Dissipation)

Provides tables detailing the heat output of system components.

2.4 IEC60601–1–2 Electromagnetic Standard Compliance & Documentation

Covers compliance with EMC standards and related documentation.

3 Structural Requirements

3.3 Floor

Covers requirements related to the floor installation.

4 Functional Requirements

4.1 Electrical Requirements

Details the electrical requirements for the Innova System, including power lines and PDB specifications.

5 Emergency

Chapter 4 Room Layouts

1 Room Layout Considerations

Provides general considerations for planning room layouts.

1.3 Clinical Access

Details clinical access requirements, including patient table clearance and CPR space.

2 Room Layout Drawings

Presents various recommended room layout configurations.

2.2 Room Layout for Innova System (example 1 & 2- Suspension rails parallel to table)

Shows example room layouts with suspension rails parallel to the table.

2.3 Room Layout for Innova System (example 3)

Presents an example room layout (example 3) with suspension perpendicular to the table.

2.4 Room Layout for Innova System (example 4)

Presents an example room layout (example 4) with suspension perpendicular to the table.

2.6 Room Layout for Innova System (example with Mobile system 9800)

Shows a room layout example with a mobile system.

Chapter 5 Physical Characteristics

1 Dimension Drawings

Directs users to dimensional drawings for system components.

2 Mounting Requirements

Provides information on floor loading and recommended mounting methods for components.

2.1 Floor Loading and Recommended Mounting Methods

Provides information on floor loading and recommended mounting methods for components.

2.2 Positioner and Table Floor Mounting

Discusses critical distances and floor mounting templates for positioner and tables.

2.3 Innova LC Positioner and Omega/InnovaIQ Table Floor Preparation Kits (GEMS supplied)

Details floor preparation kits for Innova LC and Omega/InnovaIQ Tables.

2.4 Injector Mounting Requirements

Details requirements for mounting injectors onto the table accessory rails.

Chapter 6 Electrical Connections

1 Power Distribution

Provides diagrams for AC interconnect configurations without and with Fluoro UPS.

2 Recommended Power Distribution System

Outlines the recommended power distribution system and its main functions.

3 Grounding

4 Power and Grounding Requirements

4.1 Requirements for ground cables provided by the customer

Details requirements for ground cables that the customer must provide.

4.2 Requirements for power supply cables provided by the customer

Specifies requirements for power supply cables that the customer must provide.

11 Emergency

17 Physical Runs

17.2 System Core Matrix

Explains how to interpret cable group schematics and cable length data.

17.3 PHYSICAL RUN – SYSTEM CORE DETAIL

Provides detailed specifications for system core cables, including part numbers and connectors.

20 PIST0021 - US Fluoro UPS and PDB connection

20.3.2 Connection of the Fluoro UPS Option Cables

Details the procedure for connecting the Fluoro UPS option cables.

Chapter 7 Additional Planning Aids

2 Tools and Test Equipment

Lists the necessary tools and test equipment for system components.

3 Route Survey

Outlines the process for surveying the intended delivery route.

5 Pre-Installation Checklist

A checklist used by GEHC to assess site readiness for installation.

Chapter 9 Seismic Calculations

1 Overview

Explains that seismic requirements are determined by the architect and may need agency approval.

2 Calculations

Lists the various components for which seismic calculations are included.

2.1 C1 Cabinet - Slab on Grade / Upper Floor

Provides seismic anchorage calculations for the C1 Cabinet on slab or upper floor.

2.2 C2 Cabinet - Slab on Grade / Upper Floor

Provides seismic anchorage calculations for the C2 Cabinet on slab or upper floor.

2.10 LC Positioner - Slab on Grade

Provides seismic anchorage calculations for the LC Positioner on slab.

2.11 LC Positioner - Upper Floor

Provides seismic anchorage calculations for the LC Positioner on an upper floor.

2.12 Omega IV Table - Slab on Grade

Provides seismic anchorage calculations for the Omega IV Table on slab.

2.13 Omega IV Table - Upper floor

Provides seismic anchorage calculations for the Omega IV Table on an upper floor.

2.14 Omega V Long Table w/baseplate - Slab on Grade

Provides seismic anchorage calculations for the Omega V Long Table with baseplate on slab.

2.15 Omega V Long Table w/baseplate - Upper floor

Provides seismic anchorage calculations for the Omega V Long Table with baseplate on an upper floor.

2.16 Omega V Table - Slab on Grade

Provides seismic anchorage calculations for the Omega V Table on slab.

2.17 Omega V Table - Upper floor

Provides seismic anchorage calculations for the Omega V Table on an upper floor.

2.19 InnovaIQ Table w/baseplate - Slab on Grade

Provides seismic anchorage calculations for the InnovaIQ Table with baseplate on slab.