EasyManua.ls Logo

GEA VP8002 - Detailed Technical Data

GEA VP8002
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description
Default setting
7160-9001-560
01. December 2020
14 / 74
3.1 Technical Data
Environment/thermal data (VP8002)
Operating temperature
-10 - 45 ºC [14 -113 ºF]
Transport and storage temperature -25 - 70 ºC [-13 -158 ºF]
Relative humidity 10-93%
Electrical specifications (VP8002)
Input voltage range
25 VDC,+10% ,-10%
Output voltage 25 VDC,+10% ,-10%
Power consumption 300mA
Short-circuit protected (power supply)
Inputs 2x digital
Outputs 2 x (250 mA)
2 x (4 A - CAN-Bus)
CAN bus communication 125 kbit/s,2 channels
Communication Ethernet LAN 100/10 Mbps
Firmware / Software downloadable
Protection class IP20
Internal power supply
Maximum current 2 A
Housing (7159-2853-050)
Protection rating IP 65
Geometric data
lengthxWidthxElevation
(without mounting rail)
143 x 127 x 68 mm
weight 400 g
3.2 Default setting
Other settings can be used.
For more information on this subject, please refer to the section on
Commissioning
Important!
Incorrect settings can have a negative effect on the health of the animals,
the quality of the milk and milking results.
Changes may only be carried out by trained personnel.
Check all factory settings before commissioning and adjust to the
individual requirements of the installation or animal if necessary.