Commissioning
Basics of commissioning
7160-9001-560
01. December 2020
27 / 74
Examples
Milking parlour with ethernet detection and CowScout
Two different systems with separate control units
Each control unit manages a section
Correct addressing
Melkstanderkennung
Address 01
Section
Address
Address Address
Section
Section
Address
Section
Section
Ethernet switch
S1 S2
VP8002
VP4102
VP1801
VP1801
VP8002
Address conflict due to missing section setting
Address
conflict
Address 01
Address 01
Address 02
Address 01
Address 01
Internet
VP8002
VP4102
VP1801
VP1801
VP8002
System with control unit Velos components Section
Milking Parlour Identification
System
VP8002 + VP1801 S1 Section 1
CowScout VP8002 + VP4102 S2 Section 2
Text colour Details
Green is set by DPService during installation
Red Setting must be made/selected manually
Black / Grey Factory setting of the device
For further information, please refer to the following technical information:
TI-1541 Setting information with a combination of Velos components