ADP200 Application PID-IMM User Manual Pag. 51 of 80
5.4 BASICRUN menu
BasicRun block diagram
By using this function the pump turns continuously with a basic speed or a basic pressure so the vane or the
tooth of the pump are always filled by the oil. The user has to specify a minimum speed and pressure to
activate the basic references.
Ipa
Parameter Name
Unit
Type
Default
Min
Max
11334
BRSpRefEnPerc
perc
FLOAT
0
0.00
100.00
11336
BRSpRefPerc
perc
FLOAT
0
0.00
4.50
11338
BRPrRefEnPerc
perc
FLOAT
0
0.00
100.00
11340
BRPrRefPerc
perc
FLOAT
0
0.00
4.50
11342
BRDelayTime
ms 0 0 0.00 10000.00
BasicRunSpRefEnPerc Speed reference level to activate basic run mode. If speed reference (percentages
of the nominal pump speed) is below the specified value or pressure reference
(percentages of the nominal pressure pump) is below the specified value basic run
is enabled
BasicRunSpRefPerc Speed reference in Basic Run mode
BasicRunPrRefEnPerc Pressure reference level to activate basic run mode. See also explanation of
BasicRunSpRefEnPerc
BasicRunPrRefPerc Pressure reference in Basic Run mode
BasicRunDelayTime Delay time to exit from the basic run mode when either pressure and speed
reference are greater than thresholds (Ipa 11334 & Ia 11338)