ADP200 Application PID-IMM User Manual Pag. 68 of 80
Drive 1 is the master of Drive 2 and Drive 3 are slaves, Drive 4 is Divergent Master while Drive 5 is
Divergent Slave (slave of drive 4)
Also here the master Drive 1 receive the commands (analog and digital input) and read the first pressure
feedback from the first pressure sensor now also Drive 4 is a Master so receive independent commands
from PLC and read a second pressure sensor to perform a second movement.
The machine can perform two movement in parallel (ex. Clamp open and ejector in parallel).
On master drive ”DRIVE 1Tot Number of Pumps [11300]= 5
On slave div. Master “DRIVE 4Tot Number of Pumps [11300]= 2
5.11.1 MULTIPUMP parameter list
Ipa
Parameter Name
Unit
Type
Default
Min
Max
11298
Ramp Time
-
FLOAT
0.2
0.00
10.00
11300
Tot Number of Pumps
-
UINT
1
1.00
7.00
11302
Slave Pmp Flow Ratio
-
FLOAT
1
0.10
10.00
11304
Switch Threshold
perc
INT
25
0.00
100.00
Ramp Time Not used
Tot Number of Pumps Only for Master or Slave-Div Master specify the total number of pumps that are
connected. For Slave-Div Master is the total number of pumps considering only
the divergent mode (1 or 2)
Slave Pmp Flow Ratio It is the ratio between the Master displacement and the Slave displacement.
Switch Threshold It is the Master speed threshold that makes enable the slaves