ADP200 Application PID-IMM User Manual Pag. 62 of 80
Gain Sch Sp Low Thr Gain scheduling speed low threshold.
Gain Sch Sp Med Thr Gain scheduling speed medium threshold.
Gain Sch Sp High Thr Gain scheduling speed high threshold.
MGain Digital En Enabling Gain-scheduling via a digital command or from the fieldbus (default =
ON).
MGain Dig Value Selection of the gain set from the digital command (0 default, 1, 2, 3).
MGain Term Source 1 / 2 Source selection for gain selector definition (from digital command or
fieldbus)
Prop Gain 1 Proportional gain for pressure control - set n.1.
Int Gain 1 Integral gain for the pressure control - set n.1.
Prop Gain 2 Proportional gain for pressure control - set n.2.
Int Gain 2 Integral gain for the pressure control - set n.2.
Prop Gain 3 Proportional gain for pressure control - set n.3.
Int Gain 3 Integral gain for the pressure control - set n.3.
Active Kp Press Display of the gains applied to the Kp variable.
Active Ki Press Display of the gains applied to the Ki variable.