ADP200 Application PID-IMM User Manual Pag. 64 of 80
Notch Enabler Enables notch filter on actual pressure feedback.
0=DISABLED
1=ENABLED
Notch frequency Notch filter frequency.
Notch Damp at Cut F Notch filter smoothness.
Output Notch Enabler Enables notch filter on speed feedback.
0=DISABLED
1=ENABLED
Output Notch freq Notch filter frequency.
Output Notch