EasyManuals Logo

gefran ADV200 WA DC Series User Manual

gefran ADV200 WA DC Series
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
76 ADV200 WA • Quick start up guide - Specification and installation
Step 4 - Setting the maximum speed reference value (Set max speed)
This step is used to dene the maximum motor speed value that can be reached
with each single reference signal (analog or digital).
T+ T- EN LOC ILim n:0 AL
STARTUP WIZARD
Set max speed ?
E=Yes Down=Next
E
T+ T- EN LOC ILim n:0 AL
S E Q . 0 1
PA R : 6 8 0
Full scale speed
+1500 rpm
Def: +1500
E
E
T+ T- EN LOC ILim n:0 AL
S E Q . 0 1
PA R : 6 8 0
Full scale speed
+ rpm
Def: +1500
000000750
T+ T- EN LOC ILim n:0 AL
S E Q . 0 1
PA R : 6 8 0
Full scale speed
+ 000001500 rpm
Def: +1500
After setting the speed, proceed to Step 5 to set the acceleration and deceleration
ramp parameters.
Step 5 - Setting ramp parameters (Set ramps)
Set the acceleration and deceleration times for the prole of ramp 0 :
PAR: 700 PAR: 700
Frequency
T
T+ T- EN LOC ILim n:0 AL
STARTUP WIZARD
Set ramps ?
E=Yes Down=Next
E
T+ T- EN LOC ILim n:0 AL
S E Q . 0 1
PA R : 7 0 0
Acceleration time 0
+10.00 s
Def: +10.00
T+ T- EN LOC ILim n:0 AL
S E Q . 0 2
PA R : 7 0 2
Deceleration time 0
+10.00 s
Def: +10.00
Note ! After setting the acceleration and deceleration ramps, the parameters that have been set manually and
calculated using the self-tuning procedures can be saved permanently in a non-volatile flash memory.
To save the parameters proceed to Step 6.
Step 6 - Saving parameters (Save parameters)
To save the new parameter settings, so that they are maintained also after power-
off, proceed as follows:
T+ T- EN LOC ILim n:0 AL
STARTUP WIZARD
Save parameters ?
E=Yes Down=Next
E
T+ T- EN LOC ILim n:0 AL
Save parameters
S E Q . 0 1
PA R : 5 5 0
Press E to execute
E
T+ T- EN LOC ILim n:0 AL
Save parameters
S E Q . 0 1
PA R : 5 5 0
In progress
T+ T- EN LOC ILim n:0 AL
Save parameters
S E Q . 0 1
PA R : 5 5 0
Done
T+ T- EN LOC ILim n:0 AL
STARTUP WIZARD
End of sequence !
Up=Back Down=Exit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 WA DC Series and is the answer not in the manual?

gefran ADV200 WA DC Series Specifications

General IconGeneral
Brandgefran
ModelADV200 WA DC Series
CategoryDC Drives
LanguageEnglish

Related product manuals