AFE200 • Instruction Manual 113
Menu PAR Description UM Type FB BIT Def Min Max Acc
14.2.4 4010 Fieldbus M->S enable ENUM Enable 0 1 ERWZ
Setting of eldbus data updating.
0 Disable
1 Enable
If set to 0, the possibility of sending commands and references from the drive PLC via
the eldbus is disabled.
If set to 1 the possibility of sending commands and references from the drive PLC via
the eldbus is enabled.
Menu PAR Description UM Type FB BIT Def Min Max Acc
14.2.5 4012 Fieldbus alarm mode INT32 0 0 1 ERWZ
Setting of the Opt Bus Fault alarm generation mode.
0 Off
1 On
If set to 0 the alarm is only generated if the drive is enabled.
If set to 1 the alarm is generated even with the drive disabled.
Menu PAR Description UM Type FB BIT Def Min Max Acc
14.2.6 4014 Fieldbus state ENUM Stop 0 7 R
The logic status of the eldbus connection is displayed. The value depends on the
type of bus that is used.
These logic states are displayed if the selected eldbus is CANopen:
0 Stop
1 PreOperational
2 Operational
These logic states are displayed if the selected eldbus is Probus:
3 Error
4 WaitPRM
5 WaitCFG
6 DataExchange
7 DPError
14.3 - COMMUNICATION/FIELDBUS M2S
Menu PAR Description UM Type FB BIT Def Min Max Acc
14.3.1 4020 Fieldbus M->S1 ipa FBM2SIPA 0 0 0 R
14.3.5 4030 Fieldbus M->S2 ipa FBM2SIPA 0 0 0 R
14.3.9 4040 Fieldbus M->S3 ipa FBM2SIPA 0 0 0 R
14.3.13 4050 Fieldbus M->S4 ipa FBM2SIPA 0 0 0 R
14.3.17 4060 Fieldbus M->S5 ipa FBM2SIPA 0 0 0 R
14.3.21 4070 Fieldbus M->S6 ipa FBM2SIPA 0 0 0 R
14.3.25 4080 Fieldbus M->S7 ipa FBM2SIPA 0 0 0 R