124 AFE200 • Instruction Manual
bling of the alarm. If an alarm condition occurs, the AFE product will wait for the set
time to activate the alarm. If the alarm is removed within the set time, the AFE product
will not indicate any alarm condition.
Menu PAR Description UM Type FB BIT Def Min Max Acc
15.8 4534 UndervoltAC activity ENUM Disable 0 2 RW
Setting of the behaviour of the AFE product if the Undervolt AC [9] alarm is present.
This alarm indicates a mains undervoltage condition.
0 Ignore
1 Warning
2 Disable
Menu PAR Description UM Type FB BIT Def Min Max Acc
15.9 4536 UndervoltAC restart ENUM Disable 0 1 RW
Setting of the behaviour of the AFE product if the Undervolt AC [9] alarm is present.
This alarm indicates a mains undervoltage condition.
0 Disable
1 Enable
Menu PAR Description UM Type FB BIT Def Min Max Acc
15.10 4538 UnderVAC restarttime ms UINT16 1000 0 30000 RW
Setting of the time within which the Undervolt AC [9] alarm must be removed in order
to execute automatic restart.
Menu PAR Description UM Type FB BIT Def Min Max Acc
15.11 4554 Overvolt AC activity ENUM Disable 0 2 RW
Setting of the behaviour of the AFE product if the Overvoltage AC [10] alarm is
present. This alarm indicates a mains voltage overvoltage condition.
0 Ignore
1 Warning
2 Disable
Menu PAR Description UM Type FB BIT Def Min Max Acc
15.12 4556 Overvolt AC restart ENUM Disable 0 1 RW
Enabling of automatic restart after the Overvoltage AC [10] alarm.
0 Disable
1 Enable
Menu PAR Description UM Type FB BIT Def Min Max Acc
15.13 4558 OverVAC restart time ms UINT16 1000 0 30000 RW
Setting of the time within which the Undervolt AC [9] alarm must be removed in order
to execute automatic restart.
Menu PAR Description UM Type FB BIT Def Min Max Acc
15.14 4570 Drive ovld activity ENUM Ignore 0 2 ERW
Setting of the behaviour of the AFE product in case of a Drive overload [14] alarm.