AGL50-EV 27
K1MK2MK3M
C
D
BR1
U1/L1
W1/L3
V1/L2
K1M
PE1
3 Ph
AC
mains
U2/T1
W2/T3
V2/T2
PE2
K2M K3M
L1F1
3 Ph
Motor
+
K3MK2M
-
FR
FR(R)
L02
L01
Enable
Safety contacts
Run Fwd src
Run Rev src
Freq Sel 1 src
Regulation Board
Brake cont
Power Board
Brake
Brake cont
Braking resistor
12
14
16
18
20
Src Sel Freq 2
22
Src Sel Freq 3
28
25
27
RO 2
Motor not in Alarm
21
23
RO 1
DI 1
DI 2
DI 3
DI 4
DI 5
+24Vdc
DI 3
DI 6
11
13
DO 1 (NPN)
Contactor
+24V (terminal 28)
0V (terminal 26)
Load
11
13
DO 1 (PNP)
+24V 28)(terminal
0V (terminal 26)
Load
Contactor
24
024V26
COM-DI
Fig.7.1 – Lift standard wiring
Note!
The connections indicated for command inputs represent the most common solution for an PNP typecom-
mand.
Digital I/Os with internal supply.