AGy -L 229
LCD Display DESCRIPTION LCD Selection Description
Def.
Min
Max
Unit
Variat.
IPA
PARAMETER PICK LIST
Code
[9] Out trq>thr
[10] Current lim
[11] DC-link lim
[12] Limit active
[13] Autocapt run
[14] BU overload
[15] Neg pwrfact
[16] PID err ><
[17] PID err>thr
[18] PID err<thr
[19] PIDer><(inh)
[20] PIDerr>(inh)
[21] PIDerr<(inh)
[22] FWD enc rot
[23] REV enc rot
[24] Encoder stop
[25] Encoder run
[26] Extern fault
[27] No ext fault
[28] Serial TO
[29] freq=thr1
[30] freq!=thr1
[31] freq>thr1
[32] freq<thr1
[33] freq=thr2
[34] freq!=thr2
[35] freq>thr2
[36] freq<thr2
[37] HS temp=thr
[38] HS temp!=thr
[39] HS temp>thr
[40] HS temp<thr
[41] Output freq
[42] Out freq x 2
[43] CoastThrough
[44] EmgStop
[45] DC braking
[46] Drv OL status
[47] Drv OL warn
[48] Mot OL status
[49] Reserved
[50] Reserved
[51] Contactor Active when the RUN contactor
has to be closed, either for
upward or downward motion
[52] Contactor UP Active when the RUN contactor
has to be closed for upward
motion
[53] Contactor DW Active when the RUN contactor
has to be closed for downward
motion
[54] Brake cont Active when the mechanical
brake has to be released
[55] Lift start Active when the inverter output
bridge is enabled and DC brake
is not in progress
I.101 Dig output 2 cfg Digital output 2 configuration
As for I.100 32 0 55 113
I.102 Dig output 3 cfg Digital output 3 configuration
As for I.100 54 0 55 114
I.103 Dig output 4 cfg Digital output 4 configuration
As for I.100 2 0 55 115
I.150 Exp DigOut 1 cfg Extended digital output 1 configuration
As for I.100 52 0 55 116
I.151 Exp DigOut 2 cfg Extended digital output 2 configuration
As for I.100 53 0 55 117
I.152 Exp DigOut 3 cfg Extended digital output 3 configuration
As for I.100 0 0 55 180
I.200 An in 1 Type
[0] +/- 10V 1 0 1 118
[1] 0-10V/0-20mA
I.201 An in 1 offset Analog Input 1 offset
0 -99.9 99.9 % 0.1 119
I.202 An in 1 gain Analog Input 1 gain
1 -9.99 9.99 % 0.01 120
I.203 An in 1 minimum An Input 1 minimun value
0 0 99.99 % 0.1 121
I.204 An in 1 filter Time constant of digital filter on Analog input 1
0.1 0.001 0.25 sec 0.001 122
I.205 An in 1 DeadBand Analog Input 1 dead band
0 0 99.9 % 0.01 182
Setting of the Analog Input 1 type reference (voltage)
Bipolar ± 10V
Unipolar +10V