234 AGy -L
LCD Display DESCRIPTION LCD Selection Description
Def.
Min
Max
Unit
Variat.
IPA
PARAMETER PICK LIST
Code
P.063 V/f interm volt V/F intermediate voltage
190 0 P.061 V 1 415
P.064 V/f interm freq V/F intermediate frequency
25 1.0 P.062 Hz 0.1 416
P.080 Max output freq Maximum output frequency
110 0 110 % of
F.020
1 417
P.081 Min output freq Minimum output frequency
0.0 0.0 25.0 % of
F.020
0.1 418
P.100 Slip compensat Amount of slip compensation during motoring
50 0 250 % 1 419
P.101 Slip comp filter Time constant of slip compensation
0.3 0 10 sec 0.1 420
P.102 Slip comp regen Amount of slip compensation during regeneration
50 0 250 % 1 500
P.120 Manual boost [%] Torque boost level
3025%of
P. 0 61
1 421
P.121 Boost factor src Boost level source
[0] Null Null 0 0 3 422
[1] Analog inp 1 Analog input 1
[2] Analog inp 2 Analog input 2
[3] Analog inp 3 Analog input 3
P.122 Auto boost en Automatic boost function enabling
[0] Disable Automatic boost function 0 0 1 423
[1] Enable Automatic boost function enabled
P.140 Magn curr gain Magnetizing current regulator gain
0 0 100 % 0.1 424
P.160 Osc damping gain Damping gain
10 0 100 1 425
P.170 Spd ctrl P-gainL Speed loop proportional gain (low speed)
2.0 0.0 100.0 % 0.1 501
P.171 Spd ctrl I-gainL Speed loop integral gain (low speed)
1.0 0.0 100.0 % 0.1 502
P.172 Spd ctrl P-gainH Speed loop proportional gain (high speed)
2.0 0.0 100.0 % 0.1 503
P.173 Spd ctrl I-gainH Speed loop integral gain (high speed)
1.0 0.0 100.0 % 0.1 504
P.174 Spd gain thr L Speed loop gain scheduling low threshold
0.0 0.0 F.020 Hz 0.1 507
P.175 Spd gain thr H Speed loop gain scheduling high threshold
0.0 0.0 F.020 Hz 0.1 508
P.176 Spd PI High lim Speed regulator High limit
10.0 0.0 100.0 % of
F.020
0.1 509
P.177 Spd PI Low lim Speed regulator Low limit
-10.0 -100.0 0.0 % of
F.020
0.1 510
P.178 SpdPI lim FacSrc Speed regulator limits factor source
[0] Null Null 0 0 3 511
[1] Analog inp 1 Analog input 1
[2] Analog inp 2 Analog input 2
[3] Analog inp 3 Analog input 3
P.180 SW clamp enable Current clamp enable
[0] Disable 1 0 1 426
[1] Enable
P.181 Clamp alm HldOff Holf off time for current clamp alarm. Set to maximum (25.5s) to
disable the alarm
5.0 0 25.5 s 0.1 512
P.200 Ramp CurLim mode Enable current limitation during ramp
[0] None 0 0 2 427
[1] PI Limitator
[2] Ramp freeze
P.201 Accel curr limit Current limit in acceleration phase
(*) 20 (*) % of I
nom
428
P.202 En lim in steady
[0] Disable 0 0 1 429
[1] Enable
P.203 Curr lim steady Current limit at constant speed
(*) 20 (*) % of I
nom
1 430
P.204 Curr ctrl P-gain Current limiter proportional gain
10.0 0.1 100.0 % 431
P.205 Curr ctrl I-gain Current limiter integral gain
30.0 0.0 100.0 % 0.1 432
P.206 Curr ctr feedfwd Current limiter feed-forward
0 0 250 % 1 433
P.207 Decel curr limit Current limit in deceleration phase
(*) 20 (*) % of I
nom
1 494
P.220 En DC link ctrl
[0] None None 0 0 2 434
[1] PI Limitator PI Limit regulator
[2] Ramp freeze On/Off Ramp
P.221 DC-lnk ctr Pgain DC link voltage limiter proportional gain
3.0 0.1 100.0 % 0.1 435
P.222 DC-lnk ctr Igain DC link voltage limiter integral gain
10.0 0.0 100.0 % 0.1 436
P.223 DC-link ctr FF DC link voltage limiter feed-forward
0 0 250 % 1 437
P.240 OverTorque mode Overtorque mode
[0] No Alm,Chk on 0: Overtorque detection always
active and Over-torque alarm
disabled.
0 0 3 438
[1] No Alm,Chk ss 1: Overtorque detection in steady
state and Over-torque alarm
disabled.
[2] Alm always 2: Overtorque detection always
active and Over-torque alarm
enabled.
[3] Alm steady st 3: Overtorque detection in steady
state and Over-torque alarm
enabled.
P.241 OT curr lim thr Current limit for overtorque
110 20 200 % 1 439
P.242 OT level fac src Overtorque level factor source
[0] Null Null 0 0 3 440
[1] Analog inp 1 Analog input 1
[2] Analog inp 2 Analog input 2
[3] Analog inp 3 Analog input 3
P.243 OT signal delay Delay time for overtorque signaling
0.1 0.1 25 sec 0.1 441
P.260 Motor OL prot en Enabling of motor overload protection
[0] Disable 1 0 1 444
[1] Enable
Enable current limitation in steady state
Stall prevention during dec.
for overvoltage