AGy -L 235
LCD Display DESCRIPTION LCD Selection Description
Def.
Min
Max
Unit
Variat.
IPA
PARAMETER PICK LIST
Code
P.280 BU configuration Braking unit configuration
[0] BU disabled BU disabled 1 0 2 445
[1] BU en OL dis BU enabled & Overload disable
[2] BU en OL en BU & Overload enabled
P.281 Brake res value Ohmic value of braking resistor
(*) 1 250 ohm 1 446
P.282 Brake res power Braking resistor power
(*) 0.01 25 kW 0.01 447
P.283 Br res thermal K Braking resistor thermal constant
(*) 1 250 sec 1 448
P.300 DC braking level DC braking level
75 0 100 % of I nom 1 449
P.301 DCB lev fac src DC braking level factor source
[0] Null Null 0 0 3 450
[1] Analog inp 1 Analog input 1
[2] Analog inp 2 Analog input 2
[3] Analog inp 3 Analog input 3
P.321 Autocapture Ilim Catch on flight current limit
120 20 (*) % of I nom 1 456
P.322 Demagnetiz time Demagnetization minimun time
(*) 0.01 10 sec 0.01 457
P.323 Autocap f scan t Frequency scanning time during Pick Up
1 0.1 25 sec 0.1 458
P.324 Autocap V scan t Voltage scanning time during Pick Up
0.2 0.1 25 V 0.1 459
P.340 Undervoltage thr Undervoltage threshold
0 0 80 % of P.020 1 462
P.341 Max pwrloss time Restart time from undervoltage
0 0 25 sec 0.1 463
P.342 UV alarm storage Enabling of undervoltage alarm storage
[0] Disable 1 0 1 464
[1] Enable
P.343 UV Trip Mode Undervoltage tripping mode
[0] Disabled Function disabled 0 0 2 491
[1] CoastThrough Kinetic energy recovering
[2] Emg stop Emergency stop mode
P.360 OV prevention
[0] Disable 0 0 1 465
[1] Enable
P.380 Autoreset attmps Number of autoreset attempts
0 0 255 466
P.381 Autoreset clear En. automatic reset of autorestart attempts
10 0 250 min 1 467
P.382 Autoreset delay Autoreset time delay
5 0.1 50 sec 0.1 468
P.383 Autores flt rly
[0] OFF 1 0 1 469
[1] ON
P.400 Ext fault mode External fault detection mode
[0] Alm alw,No AR - Drive in alarm. Alarm always
active. Alarm autoreset is not
possible.
0 0 3 470
[1] Alm run,No AR - Drive in alarm. Alarm active
only with running motor. Alarm
autoreset is not possible.
[2] Alm alw, ARes - Drive in alarm. Alarm always
active. Alarm autoreset is
possible.
[3] Alm run, ARes - Drive in alarm. Alarm active
only with running motor. Alarm
autoreset is possible.
P.410 Ph Loss detec en Phase Loss detection enabling
[0] Disable 1 0 1 492
[1] Enable
P.420 Volt reduc mode Voltage reduction mode
[0] Always Always 0 0 1 471
[1] Steady state Costant speed only
P.421 V reduction fact
100 10 100 % of P.061 1 472
P.422 V fact mult src Source of voltage reduction factor multiplier
[0] Null Null 0 0 3 473
[1] Analog inp 1 Analog input 1
[2] Analog inp 2 Analog input 2
[3] Analog inp 3 Analog input 3
P.440 Frequency thr 1 Frequency 1 level detection
0.5 0 F.020 Hz 0.1 474
P.441 Freq prog 1 hyst Hysteresis amplitude related to P-420
0.2 0 F.020 Hz 0.1 475
P.442 Frequency thr 2 Frequency 2 level detection
0 0 F.020 Hz 0.1 476
P.443 Freq prog 2 hyst Hysteresis amplitude related to P-422
0.5 0 F.020 Hz 0.1 477
P.460 Const speed tol Tolerance at constant speed
0 0 25 Hz 0.1 478
P.461 Const speed dly Ramp end signalling delay
0.1 0 25 sec 0.1 479
P.480 Heatsnk temp lev Heatsink temperature signalling level
70 10 110 °C 1 480
P.481 Heatsnk temp hys Hysteresis band related to P.480
5 0 10 °C 1 481
P.500 Switching freq Modulation frequency
[0] 1kHz (*) 0 (*) 482
[1] 2kHz
[2] 3kHz
[3] 4kHz
[4] 6kHz
[5] 8kHz
[6] 10kHz
[7] 12kHz
[8] 14kHz
[9] 16kHz
[10] 18kHz
Alarm relay contacts behaviour during autoreset
Automatic PickUp enabling after Overvoltage