238 AGy -L
LCD Display DESCRIPTION LCD Selection Description
Def.
Min
Max
Unit
Variat.
IPA
PARAMETER PICK LIST
Code
C.000 Save parameters Save parameters command
(1) No action. (1) (1) (2) 800
(2) Save parameters command.
C.001 Recall param Recall last set of saved parameters
(1) No action. (1) (1) (2) 801
(2) Recall last set of saved
parameters.
C.002 Load default Recall of the factory parameters.
(1) No action. (1) (1) (2) 802
(2) Load default parameters.
C.020 Alarm clear Reset of the the Alarm List register
(1) No action. (1) (1) (2) 803
(2) Clear alarm register command.
C.040 Recall key prog
(1) No action. (1) (1) (2) 804
(2) Recall parameter from PRG-KEY
key.
C.041 Save pars to key
(1) No action. (1) (1) (2)
(2) Storage of parameters to PRG-
KEY key.
C.050 Rst mdplc prec run
(1) No action. (1) (1) (2) 809
(2) Reset mdplc error
C.060 Calculate space
(1) No action. (1) (1) (2) 809
(2) Start
C.070 Recall kbg prog
(1) No action. (1) (1) (2) 809
(2) Recall pars from keypad
C.071 Save pars to kbg Storage of parameters into LCD keypad
(1) No action. (1) (1) (2) 810
(2) Store pars into keypad
C.100 Measure stator R Motor Autotune command
(1) No action. (1) (1) (2) 806
(2) Autotune command.
H.000 Virtual digital command
0 0 255 1000
H.001 Exp virtual digital command
0 0 255 1001
H.010 Virtual digital state
0 0 255 1002
H.011 Exp Virtual digital state
0 0 255 1003
H.020 Virtual An Output 1
0 -32768 32767 1004
H.021 Virtual An Output 2
0 -32768 32767 1005
H.022 Exp Virtual An Output 1
0 -32768 32767 1006
H.030 Profidrive Control word (see Profibus instruction manual)
0 0 65535 1007
H.031 Profidrive Status word (see Profibus instruction manual)
0 0 65535 1008
H.032 Profidrive reference (see Profibus instruction manual)
0 -16384 16383 1040
H.033 Profidrive actual reference (see Profibus instruction manual)
1 -16384 16383 1041
H.034 Drive status
0 0 65535 1042
H.040 Progress
0 0 100 1009
H.050 Drive output frequency at 32bit (LSW) (d.000)
0
-2
31
2
31
-1
1010
H.051 Drive output frequency at 32bit (MSW) (d.000)
0
-2
31
2
31
-1
1011
H.052 Drive reference frequency at 32bit (LSW) (d.001)
0
-2
31
2
31
-1
1012
H.053 Drive reference frequency at 32bit (MSW) (d.001)
0
-2
31
2
31
-1
1013
H.054 Output speed (d.000)*(P.600) at 32bit (LSW) (d.007)
0
-2
31
2
31
-1
1014
H.055 Output speed (d.000)*(P600)at 32bit (MSW) (d.007)
0
-2
31
2
31
-1
1015
H.056 Speed Ref (d.001)*(P.600) at 32bit (LSW) (d.008)
0
-2
31
2
31
-1
1016
H.057 Speed Ref (d.001)*(P.600) at 32bit (MSW) (d.008)
0
-2
31
2
31
-1
1017
H.058 Encoder freq at 32bit (LSW) (d.301)
0
-2
31
2
31
-1
1018
H.059 Encoder freq at 32bit (MSW) (d.301)
0
-2
31
2
31
-1
1019
H.060 Encoder speed (d.000)*(P.600) at 32bit (LSW) (d.302)
0
-2
31
2
31
-1
1044
H.061 Encoder speed (d.000)*(P.600) at 32bit (MSW) (d.302)
0
-2
31
2
31
-1
1045
H.062 Bitwise reading of active alarms (bit 0 to 15). Each bit is
associated to a specific alarm, according to table 9.3.1.
00
2
31
-1
1060
This menu is not available on the keypad. The setting and the reading of the parameters here contained, can be performed exclusively via serial line or through SBI card.
805
Storage of the inverter parameter on the external key
Recall of parameters from LCD keypad
HIDDEN
Reset mdplc error at previous run
Off line space evaluation
COMMAND
Recall of the parameters in the external key

Table of Contents

Related product manuals