20 Product description OptiStar CG08(-C)
Keyboard lock
The OptiStar CG08(-C) gun control unit has a keyboard lock to prevent
modification of individual parameter values kV, µA etc.) within the
operating modes (Program and Preset). Following is not affected by the
keyboard lock:
- Program selection
- Display of desired values of the current program
- Displaying the actual values
- Error acknowledgement
An active keyboard lock is indicated by a blinking of the remote display.
(see also "Initial start-up - Activate/deactivate the keyboard lock")
The keyboard lock status remains stored, when switching the equipment
off and on. The keyboard lock is cancelled if a RAM reset is performed.
On the OptiStar CG08(-C) gun control unit (automatic device), an
external interlocking by remote input can also take place. These two
locking features are independent, which means, if the local interlocking is
deactivated, the external interlocking remains activated and vice versa.
Background illumination
Brightness
8 different brightness settings are available for the display. The setting
remains in place when the machine is switched on/off.
Auto Power Save mode
If no powder is being applied, then the background lighting turns off
automatically 5 minutes after a button has been pressed last time.