EasyManuals Logo

Gema OptiStar CG08-C User Manual

Gema OptiStar CG08-C
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
V 02/18
OptiStar CG08(-C) Fault remedying 49
Code Description Criteria Remedy
H47
No CAN interface installed
CAN interface is selected in the
system parameters, but no interface
is installed
contact Gema Service
H48
No ACK to "Boot Up
Message" received
No CAN node is answering to the
"Boot Up Message".
Check cabling connections
between the users, otherwise
contact Gema service
Motor throttles:
H60
Conveying air reference
position not found
Throttle motor or needle jammed,
limit switch defective, error in motor
throttle
contact Gema Service
H61
Supplementary air reference
position not found
Throttle motor or needle jammed,
limit switch defective, error in motor
throttle
contact Gema Service
H62
Electrode rinsing air
reference position not found
Throttle motor or needle jammed,
limit switch defective, error in motor
throttle
contact Gema Service
H64
Conveying air throttle does
not move
Short circuit in limit switch, motor
throttle defective
contact Gema Service
H65
Supplementary air throttle
does not move
Short circuit in limit switch, motor
throttle defective
contact Gema Service
H66
Electrode rinsing air throttle
does not move
Short circuit in limit switch, motor
throttle defective
contact Gema Service
H68
Conveying air position lost
Lost steps, limit switch defective,
throttle motor defective
contact Gema Service
H69
Supplementary air position
lost
Lost steps, limit switch defective,
throttle motor defective
contact Gema Service
H70
Electrode rinsing air position
lost
Lost steps, limit switch defective,
throttle motor defective
contact Gema Service
Communication Mainboard-Gun:
H90
Communication error
Mainboard
Mainboard defective contact Gema Service
H91
Communication error
Mainboard-Gun
Gun, gun cable or Mainboard
defective
Replace or contact Gema
Service
H92
Communication error
Mainboard
Mainboard defective contact Gema Service
Help codes list
The last appeared four errors are stored in a list by the software. If an
error appears, which is already in the list, he will not be listed again.
Appearance of errors
It is possible that an error is only displayed for a short time, but after the
acknowledgement it will disappear. In this case, it's recommended to
switch off the control unit and switch it on again (reset by restarting).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gema OptiStar CG08-C and is the answer not in the manual?

Gema OptiStar CG08-C Specifications

General IconGeneral
BrandGema
ModelOptiStar CG08-C
CategoryControl Unit
LanguageEnglish

Related product manuals