V 02/18
OptiStar CG08(-C) Initial start-up 41
Activate/deactivate the keyboard lock
1. Hold key pressed
2. Press
key
The keyboard lock is activated. The remote display blinks.
3. The keyboard lock is cancelled by pressing the same key
combination
Checking the software version
4. Press these two keys at the same time
5.
The status display is shown as long as the keys are held.
RAM Reset
The RAM reset enables a restore of factory settings of the OptiStar CG08
gun control unit. All parameters (except P00) and correction values as
well as all user-defined values in the Program mode and Preset mode will
be overwritten with factory default. An active keyboard lock will be
deactivated.
NOTE:
By resetting the RAM, all user-made settings will be set to factory
default!
1. Switch off the control unit
2. Press the
key and hold it
3. Switch on the control unit, the CLR display blinks
4. Wait for approximately 5 seconds, until CLR disappears
5. Release the
key