25
Adjustable Frequency Drive
Terminals Together
Connect All TM1
(Main Power Disconnected)
to All
AC Line Inputs
Machine or Equipment Frame
Connect Hi-Pot
High Voltage Dielectric Withstand Tester (Hi-Pot Tester)
Motor Wires
Frame
MAX
VOLTAGE
10mA0mA
LEAKAGE
RESETH. V.
R
Chassis
L2
L1
T2
T3
T1
AC Line Input
ZERO
L1
Auxiliary Equipment
L3
P
L2
RETURN TEST
Chassis
AC KILOVOLTS
0
12
3
FIGURE 12 – HI-POT SETUP