TECHNICALDATA

 

Boiler,typeC13,C33,C43
    
Gascategory l
2H
l
2H
l
2H
SEDBUK2005rating % 90.4 90.4 90.5
SEDBUK2009rating % 89.5 89.1 89.4

Maximumheatinginputpower kW 12.3 18.5 30.6
Minimumheatingoutput
powerat80/60°C(Pmin.)
kW 3.9 4.9 8.5
Maximumheatingoutput
powerat80/60°C(Pmax.)
kW 12 18.2 30
Minimumheatingoutput
powerat50/30°C(Pmin.)
kW 4.4 5.4 9.3
Maximumheatingoutput
powerat50/30°C(Pmax.)
kW 13.2 19.6 32.8
Minimumheatingtemperature °C 10 10 10
Maximumheating
temperature
°C 80 80 80
Minimumheatingowrate l/h 400 400 400
Contentofheatingexpansion
vessel
l 8 8 8
gallons 1.76 1.76 1.76
Heatingexpansionvessel
presetpressure
bar 0.75 0.75 0.75
psi 10.9 10.9 10.9
Maximumheatingsystem
volume(approx)
l 160 160 160
Heatingsafetyvalvepreset
pressure(PMS)
bar 3 3 3
psi 36/3 36/3 36/3

ApplianceNOxclass 5 5 5

Electricalsupply V/Hz
230V
50Hz
230V
50Hz
230V
50Hz
Standbymodeelectrical
power
W 6 6 6
Operationalmodeelectrical
power(Max)
W 151 151 151
Internalfuseratingonmain
PCB
A 2 2 2
Indexofelectricalprotection
(EN60529)
IPX4D IPX4D IPX4D
    
GasconnectionØO.D. mm
15
(copper)
15
(copper)
15
(copper)
Heatingflowandreturn
connectionØO.D.
mm
22
(copper)
22
(copper)
22
(copper)
CondensateconnectionØI.D. mm
21.5
(plastic)
21.5
(plastic)
21.5
(plastic)
Safetyvalvedischarge
connectionØO.D.
mm
15
(copper)
15
(copper)
15
(copper)
Liftweight
kg 37.1 37.1 38.3
lb 81.8 81.8 84.5
Totalweight(installed) kg 42 43 43
NumberofCEcerticate
1312
BU
5333
1312
BU
5334
1312
BV
5336
    

Maximumheatinggasow
rate
m
/h
1.3 1.96 3.24
Minimumgasowrate
m
/h
0.43 0.54 0.92
CO2atQmax+"tolerance
caseON"
%
9.2±
0.3%
9.2±
0.3%
9.2±
0.3%
CO2atQmax+"tolerance
caseOFF"
%
9±
0.2%
9±
0.2%
9±
0.2%
CO2atQmin+
"tolerancecaseON"
%
8.9±
0.3%
8.9±
0.3%
8.9±
0.3%
CO2atQmin+
"tolerancecaseOFF"
%
8.7±
0.2%
8.7±
0.2%
8.7±
0.2%
Inletpressure mbar 20 20 20

Maximumheatinggasow
rate
kg/h - 1.44 2.37
Minimumgasowrate kg/h - 0.4 0.67
CO2atQmax+"tolerance
caseON"
% -
10.3±
0.3%
10.3±
0.3%
CO2atQmax+"tolerance
caseOFF"
% -
10.1±
0.2%
10.1±
0.2%
CO2atQmin+
"tolerancecaseON"
% -
9.8±
0.3%
9.8±
0.3%
CO2atQmin+
"tolerancecaseOFF"
% -
9.6±
0.2%
9.6±
0.2%
Inletpressure mbar 37 37 37

Table of Contents

Other manuals for Glow-worm Ultracom2 sxi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Ultracom2 sxi and is the answer not in the manual?

Glow-worm Ultracom2 sxi Specifications

General IconGeneral
BrandGlow-worm
ModelUltracom2 sxi
CategoryBoiler
LanguageEnglish

Related product manuals