0020112600_02-10/12-Glow-worm
- 30 -
INSTALLATION
• Pressbutton or underthesymbol tochoosethetest
modethatyouwishtolaunch.
• Testmode"P.01":
- Pressbutton
todisplaytheburnerforcingsetting.The
screendisplays"P.01"and"0".
- Pressonbutton
or underthesymbol tomodifythe
valueofthesettingfrom"0"(0%)to"100"(100%).
- Pressonbutton
for1secondtoexitthesubmenuor
formorethan7secondstoaccessthecongurationmenu.
• Testmode"P.02"to"P.07":
- Press
tolaunchthetestmode.Thescreendisplays
"P.0X"and"On".
- Thetestmodewillbeautomaticallystopafter15minutes.
• Whenyouhavenished,presstheresetbutton
orthe
On/Offbuttontoexitthetestmodes.
P.01
Forcingthe
adjustable-
powerburner
whenheating
Theappliancefunctionsatapower
adjustablefrom"0"(0%=Pmin.)to"100"
(100%=Pmax.)byusingbuttons
or
underthesymbol aftersuccessful
ignition.
P.02
Forcingthe
burnerto
heatingignition
power
Theappliancefunctionsatignitionpower
aftersuccessfulignition.
P.03
Forcingthe
burnerto
HeatingPmax.
Theappliancefunctionsatitsmaximum
poweraftersuccessfulignition.
P.05
Fillingthe
appliance
The3wayvalveisinthecentralposition,
thepumpandtheburnerstopsothat
theappliancecanbelled.Smartwiring
centre/ebusonly.
P.06
Ventingthe
installation
Thefunctionisactivatedforaperiodof5
minutesontheheatingcircuit.
Makesurethattheairventisopen.
P.07
Ventingthe
appliance
Thefunctionisactivatedforaperiodof5
minutesontheshortcircuit.
Makesurethattheairventisopen.
Thecombustionforthisappliancehasbeenpre-setatthe
factoryforoperationonNaturalGasG20asdenedonthe
appliancedatalabel.
Noadjustmentofthecombustionisnecessary.
Ifyouwishtocheckthecombustionthenfollowtheinstructions
intheServicingsection.
• Oncetheapplianceisinstalled,checktheoperationofthe
appliance.
• Starttheappliancetoensurethatanyadjustmentsoperate
correctlyandcheckthattheapplianceoperatessafely.
• Checkthegas-tightnessandwater-tightnessoftheappliance
andeliminateanyleaks.
• Checkthattheuejointsaretestedfortightnessandttedin
accordancewiththeinstructions.
• Checktheentirecontrolandsafetysystem,itssettingsand
itsoperation.
Attheendoftheinstallation,theinstallermust:
- explaintheoperationoftheapplianceanditssafetydevices
totheuser,ifnecessaryprovideademonstrationandanswer
anyquestions;
- handovertotheuseralltherequireddocumentation,
- llinthedocumentswherenecessary;
- advisetheuseroftheprecautionsnecessarytoprevent
damagetothesystem,applianceandthebuilding;
- remindtheusertoservicetheapplianceannually.
• Drawattention,ifapplicable,tothecurrentissueofthe
GasSafety(InstallationandUse)Regulations,Section35,
whichimposesadutyofcareonallpersonswholetoutany
propertycontainingagasapplianceintheUK.
Theusershallnotinterferewithoradjustsealedcomponents.
ItistheLawthatanyservicingiscarriedoutbya
approvedatthetimebytheHealthandSafety
Executive.
• Advisetheuserthat,likeallcondensingboilersthis
appliancewillproduceaplumeofcondensationfromtheue
terminalincoolweather.Thisisduetothehighefciency
andlowuegastemperatureoftheboiler.
• Advisetheuserthatthepermanentmainselectricalsupply
shouldnotbeswitchedoff,asthebuiltinfrostprotectionand
pumpexerciseprogramwillnotoperate.
• AdvisetheUserifthemainselectricityandgasaretobe
turnedoffforanylongperiodsduringsevereweather,itis
recommendedthatthewholesystem,includingtheboiler,
shouldbedrainedtoavoidtheriskoffreezing.
i
Sealed system: The system must be relled and
to the correct pressure as indicated in these
instructions
• Leavetheseinstructionsandthe‘Benchmark’Installation,
CommissioningandServiceRecordwiththeuser.