0020112600_02-10/12-Glow-worm
- 19 -
INSTALLATION
L
3
2
1
5
4
B
A
Ø60/100 10m
Eachtimeanadditional90°bendisnecessary(or2at45°),the
length(L)mustbereducedby1m.
Exhaustmassrate(g/s)
Atminthermalload(40°C/30°C) 1.9 2.4 4.1
Atmaxthermalload(80°C/60°C) 5.5 8.3 13.8
Exhausttemperature(°C)
Atminthermalload(40°C/30°C) 47 45 41
Atmaxthermalload(80°C/60°C) 69 65.7 71.4
24
V
230
V
A
A
B
1
2
• Undothetwoscrews(2)ontheundersideofthefrontpanel
andremovethefrontpanel(1).
e
Incorrect installation can cause electric shock or
appliance damage. The electrical connection of
the appliance must be made only by a qualied
engineer.
Theappliancemustbeconnecteddirectlytoanaccessible,
xed,switched,electricaloutlet.
Theexternalwiringmustbeearthed,withcorrectpolarityandin
accordancewithcurrentstandards.
Themanufacturerdeclinesanyresponsibilityfordamagesto
personsorotherscausedbytheincorrectinstallationofthe
applianceearthing.Thisincludesfailuretocomplywithcurrent
standards.
Electricalcomponentshavebeentestedtomeettheequivalent
requirementsoftheBEAB.
• Donotusecablegreaterthan10mmindiameterforthe
electricalconnections.
Allsystemcomponentsmustbeofanapprovedtype.
• Donotinterruptthemainssupplywithatimeswitchor
programmer.
Theboilerissuitableforinstallationinbathroomzones2and3.