Loading...
0020112600_02-10/12-Glow-worm
- 20 -
INSTALLATION
 
2
1
4
3

 
 
 
 
 
30mm
max
1
2
3

 
 
 
Whenyouconnecttheelectricalwirestoaconnectoronthe
electronicboard:
• Keepadistanceofamaximumof30mmbetweenconnector
(1)andthestartoftheinsulation(3).
• Ifusingsinglecorewiresareused(2)ensurethattheare
wrappedtogetherinaninsulatingsheath.
• Fixthecablesinthecable-clampontheeBox.
 
Connectionofthewholeelectricalsystemandanyheating
systemcontrolstotheelectricalsupplymustbethrougha
commonisolator.
Isolationshouldpreferablybebyadoublepoleswitchedfused
spurboxhavingaminimumcontactseparationof3mmoneach
pole.Thefusedspurboxshouldbereadilyaccessibleand
preferablyadjacenttotheboiler.Itshouldbeidentiedastoits
use.
Afusedthreepinplugandshutteredsocketoutletmaybeused
insteadofafusedspurboxprovidedthatitisnotusedina
roomcontainingaxedbathorshower.
24
V
1

 
• Connecttheappliance'spowercabletothe230Vsingle-
phasenetwork+earth.
• Connecttheappliancecorrectlytotheliveandneutral
connections.