MAINTENANCE
 
1
2

 
 
• Checktheexpansionvessel'ssupplypressure(see«
TechnicalData»chapter)bymeansofthepressureinlet
locatedontheexpansionvessel.Adjustthepressureif
necessary.
• Followingtheinstallationofanewexpansionvessel,lland
purgetheapplianceorinstallation,ifnecessary.
 
a
Warning: condensate is mildly acidic. Use
protective gloves.
1
1
2
3
4
5

 
 
 
 
 
• Placeacontainerunderthecondensatetrap(1).
• Removethesiphon(3)fromthecondensatetrapandclean.
• Disconnectthecondensationdischarge(2).
• Disconnecttheheatexchangerhose(5).
• Removethecondensatetrap(1)usingtheclips(4).
• Cleanthehose,thetrapandthesiphon,removeany
accumulateddirt.
• Reassemblethecomponents,takingcaretopositionthe
gasketscorrectly.
• Startthesiphon(3)andllwithwater.