0020112600_02-10/12-Glow-worm
- 39 -
MAINTENANCE
Ifafterservicingandadjustmentoftheappliancethe
combustionvaluesarestillunacceptableandafterfurther
remedialworkhasbeencarriedout,theappliancemustbe
disconnecteduntiltheCO/CO2ratioisacceptable.
• AdvicecanbesoughtfromtheGlow-wormTechnical
Helpline.
i
If the annual check of combustion CO2, CO/CO2 ratio
checks did not require adjustment and the inspections
described in "Preliminaries" were satisfactory then it
will not be necessary to complete a full service.
Allroutineservicingrequirementscanbeachievedbythe
removalofthefrontpanel.
• Positionthecontrolboxintotheserviceposition.
• Beforecommencingwithaserviceorreplacementofparts,
isolatetheboilerfromtheelectricalandgassupplies.
• Refertotheserviceintervalrecordlocatedontheinside
backpagesofthisdocument.
12sxi / 18sxi
A
B
C
3
2
1
• Removethesilencerretainingscrews(1)andremovethe
silencer(3).
• Cleantheinteriorofthesilencerwithadryclothifnecessary,
takingcarenottodamagetheinternalfoam.
• Repeattheoperationinreverseordertoreplacethesilencer.
30sxi
A
1
2
3
• Unclipandremovethesilencer(3).
• Cleantheinteriorofthesilencerwithadryclothifnecessary,
takingcarenottodamagetheinternalfoam.