Page #9 background imageLoading...
Page #9 background image
0020112600_02-10/12-Glow-worm
- 7 -
INTRODUCTION
Gas Supply
Thegasinstallationmustbeinaccordancewiththerelevant
standards.
InGB,thisisBS6891.
InIE,thisisthecurrenteditionofI.S.813“DomesticGas
Installations”.
Thesupplyfromthegovernedmetermustbeofadequatesize
toprovideasteadyinletworkingpressureof20mbar(8inwg)at
theboiler.Oncompletion,testthegasinstallationfortightness
usingthepressuredropmethodandsuitableleakdetection
uid,purgeinaccordancewiththeabovestandard.
Domestic Hot Water
Alldomestichotwatercircuits,connections,ttingsmustbe
inaccordancewiththerelevantstandardsandwatersupply
regulations.
GB:GuidanceG17toG24andrecommendationR17toR24of
theWaterRegulationsGuide.
IE:ThecurrenteditionofI.S.813“DomesticGasInstallations”.
Heating System
InGB,itisnecessarytocomplywiththeWaterSupply(Water
Fittings)Regulations1999(forScotland,theWaterByelaws
2000,Scotland).TocomplywiththeWaterregulationsyour
attentionisdrawnto:TheWaterRegulationsguidepublished
bytheWaterRegulationsAdvisoryService(WRAS)givesfull
detailsoftherequirements.
InIE,therequirementsgiveninthecurrenteditionofI.S.813
“DomesticGasInstallations”andthecurrentBuilding
Regulationsmustbefollowed.
Electrical Supply
TheboilerMUSTbeearthed.Allsystemcomponentsshall
beofanapprovedtypeandallwiringtocurrentI.E.E.wiring
regulations.Externalwiringmustbecorrectlyearthed,polarised
andinaccordancewiththerelevantstandards.
InGB,thisisBS7671.
InIE,thisisthecurrenteditionofETCIrules.
TheboilerMUSTbeconnectedtoapermanent230Vac,50Hz
supply.
Connectionofthewholeelectricalsystemoftheboiler,including
anyheatingcontrols,totheelectricalsupplyMUSTbethrough
onecommonisolatorandmustbefused3Ampmaximum.
Isolationshouldbebyadoublepoleswitchedfusedspurbox,
withaminimumgapof3mmforbothpoles.Thefusedspur
boxshouldbereadilyaccessibleandpreferablyadjacenttothe
appliance.Itshouldbeidentiedastoitsuse.
Alternativelyconnectioncanbemadethroughanunswitched
shutteredsocketand3Afused3-pinplugbothtothecurrent
issueofBS1363,providedtheyarenotusedinaroom
containingabathorshower.
WiringtotheboilermustbePVC85OCinsulatedcable,notless
than0.75mm2(24/0.20mm).
 
Gas Safety (Installation and Use) Regulations
Inyourowninterestsandthatofsafety,itistheLawthatALL
gasappliancesareinstalledbyacompetentpersonapprovedat
thetimebytheHealthandSafetyExecutiveinaccordancewith
thecurrentissueoftheseregulations.
Control of Substances Hazardous to Health
UnderSection6ofTheHealthandSafetyatWorkAct1974,we
arerequiredtoprovideinformationonsubstanceshazardousto
health.Theadhesivesandsealantsusedinthisapplianceare
curedandgivenoknownhazardinthisstate.
InsulationPads:
Thesecancauseirritationtoskin,eyesandtherespiratory
tract.Ifyouhaveahistoryofskincomplaintyoumaybe
susceptibletoirritation.Highdustlevelsareusualonlyifthe
materialisbroken.
Normalhandlingshouldnotcausediscomfort,butfollownormal
goodhygieneandwashyourhandsbeforeeating,drinkingor
goingtothelavatory.
• Ifyoudosufferirritationtotheeyesorsevereirritationtothe
skinseekmedicalattention.
 
i
The recycling of the packaging must be carried
out by the qualied professional who installed the
appliance.
 
Mostoftheapplianceismadeofrecyclablematerials.
This symbol indicates that this appliance must not
be disposed of with household waste, that it should
be selectively collected for energy recovery, reuse
or recycling.
• Taketheappliancetoanappropriatecollectionpoint.
i
By complying with this directive, you will contribute
to the preservation of natural resources and the
protection of human health.
 
Werecommendthatyourecyclethepackagingoftheappliance
inaresponsiblefashion.
• Sortthewasteinordertoseparatethoseelementswhich
canberecycled(cardboard,plastics...)andthosewhich
cannotberecycled.
• Eliminatethewasteinaccordancewithexistingregulations.

Table of Contents

Other manuals for Glow-worm Ultracom2 sxi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Ultracom2 sxi and is the answer not in the manual?

Glow-worm Ultracom2 sxi Specifications

General IconGeneral
BrandGlow-worm
ModelUltracom2 sxi
CategoryBoiler
LanguageEnglish

Related product manuals