Gas Supply
Thegasinstallationmustbeinaccordancewiththerelevant
standards.
InGB,thisisBS6891.
InIE,thisisthecurrenteditionofI.S.813“DomesticGas
Installations”.
Thesupplyfromthegovernedmetermustbeofadequatesize
toprovideasteadyinletworkingpressureof20mbar(8inwg)at
theboiler.Oncompletion,testthegasinstallationfortightness
usingthepressuredropmethodandsuitableleakdetection
uid,purgeinaccordancewiththeabovestandard.
Domestic Hot Water
Alldomestichotwatercircuits,connections,ttingsmustbe
inaccordancewiththerelevantstandardsandwatersupply
regulations.
GB:GuidanceG17toG24andrecommendationR17toR24of
theWaterRegulationsGuide.
IE:ThecurrenteditionofI.S.813“DomesticGasInstallations”.
Heating System
InGB,itisnecessarytocomplywiththeWaterSupply(Water
Fittings)Regulations1999(forScotland,theWaterByelaws
2000,Scotland).TocomplywiththeWaterregulationsyour
attentionisdrawnto:TheWaterRegulationsguidepublished
bytheWaterRegulationsAdvisoryService(WRAS)givesfull
detailsoftherequirements.
InIE,therequirementsgiveninthecurrenteditionofI.S.813
“DomesticGasInstallations”andthecurrentBuilding
Regulationsmustbefollowed.
Electrical Supply
TheboilerMUSTbeearthed.Allsystemcomponentsshall
beofanapprovedtypeandallwiringtocurrentI.E.E.wiring
regulations.Externalwiringmustbecorrectlyearthed,polarised
andinaccordancewiththerelevantstandards.
InGB,thisisBS7671.
InIE,thisisthecurrenteditionofETCIrules.
TheboilerMUSTbeconnectedtoapermanent230Vac,50Hz
supply.
Connectionofthewholeelectricalsystemoftheboiler,including
anyheatingcontrols,totheelectricalsupplyMUSTbethrough
onecommonisolatorandmustbefused3Ampmaximum.
Isolationshouldbebyadoublepoleswitchedfusedspurbox,
withaminimumgapof3mmforbothpoles.Thefusedspur
boxshouldbereadilyaccessibleandpreferablyadjacenttothe
appliance.Itshouldbeidentiedastoitsuse.
Alternativelyconnectioncanbemadethroughanunswitched
shutteredsocketand3Afused3-pinplugbothtothecurrent
issueofBS1363,providedtheyarenotusedinaroom
containingabathorshower.
WiringtotheboilermustbePVC85OCinsulatedcable,notless
than0.75mm2(24/0.20mm).
Gas Safety (Installation and Use) Regulations
Inyourowninterestsandthatofsafety,itistheLawthatALL
gasappliancesareinstalledbyacompetentpersonapprovedat
thetimebytheHealthandSafetyExecutiveinaccordancewith
thecurrentissueoftheseregulations.
Control of Substances Hazardous to Health
UnderSection6ofTheHealthandSafetyatWorkAct1974,we
arerequiredtoprovideinformationonsubstanceshazardousto
health.Theadhesivesandsealantsusedinthisapplianceare
curedandgivenoknownhazardinthisstate.
InsulationPads:
Thesecancauseirritationtoskin,eyesandtherespiratory
tract.Ifyouhaveahistoryofskincomplaintyoumaybe
susceptibletoirritation.Highdustlevelsareusualonlyifthe
materialisbroken.
Normalhandlingshouldnotcausediscomfort,butfollownormal
goodhygieneandwashyourhandsbeforeeating,drinkingor
goingtothelavatory.
• Ifyoudosufferirritationtotheeyesorsevereirritationtothe
skinseekmedicalattention.
i
The recycling of the packaging must be carried
out by the qualied professional who installed the
appliance.
Mostoftheapplianceismadeofrecyclablematerials.
This symbol indicates that this appliance must not
be disposed of with household waste, that it should
be selectively collected for energy recovery, reuse
or recycling.
• Taketheappliancetoanappropriatecollectionpoint.
i
By complying with this directive, you will contribute
to the preservation of natural resources and the
protection of human health.
Werecommendthatyourecyclethepackagingoftheappliance
inaresponsiblefashion.
• Sortthewasteinordertoseparatethoseelementswhich
canberecycled(cardboard,plastics...)andthosewhich
cannotberecycled.
• Eliminatethewasteinaccordancewithexistingregulations.