INSTALLATION

i
All the drawings dimensions are shown in mm.
 
 
 
Beforechoosingasitefortheappliance,carefullyreadthe
safetywarningsandinstallationmanual.
• Ensurethatwalltowhichtheappliancewillbemountedonis
structurallysafeinordertosupporttheweightoftheappliance.
• Ensurethatthespacethattheapplianceistobeinstalled
withinallowstheappliancetobeinstalledandtheclearances
maintained.Thiswillensurethattheconnectionstothe
water,gasanduecanbeaccessedandinspected(see
chapterClearances).
• Explaintheserequirementstotheapplianceuser.
• Donotinstalltheapplianceaboveanotherappliancethat
coulddamageit(forexample,aboveacookerthatmight
emitsteamorgrease)orinaroom,whichhasalotofdustin
theatmospherewhichiscorrosive.
• Theboilermustbettedinsidethepropertyandexposed
pipeworkmayneedtobeprotectedfromfrostbyttinga
frostthermostat.
 
Location
Thisboilerisnotsuitableforoutdoorinstallation.
Thisboilermaybeinstalledinanyroom,althoughparticular
attentionisdrawntotheinstallationofaboilerinaroom
containingabathorshowerwherereferencemustbemadeto
therelevantrequirements.
Thisboilerissuitableforinstallationinbathroomzones2and3.
thisisthecurrentI.E.E.WIRINGREGULATIONSand
BUILDINGREGULATIONS.
referenceshouldbemadetothecurrenteditionofI.S.813
“DomesticGasInstallations”andthecurrentETCIrules.
Timber Frame Buildings
Iftheboileristobeinstalledinatimberframebuildingitshould
bettedinaccordancewiththeInstituteofGasEngineers
documentIGE/UP/7/1998.
 
• Toallowperiodicmaintenance,ensurethedistances
indicatedonthediagram.
Additionalclearancesmaybebenecialaroundtheboilerfor
installationandservicing.
Forueinstallationswhereexternalaccessisnotpracticable,
considerationshouldbegivenforthespacerequiredtoinsert
theuefrominsidetheproperty,whichmaynecessitate
clearancelargerthanthosespeciedindiagrambelow.
ØA
ØA + 5 min.
600*
min.
0
min.
0
min.
200
min.
150
min.
600*
min.
0
min.
0
min.
200
min.
150
min.

 


Theboileranduearesuitableforinstallationontoandthrough
combustiblematerialsprovidedthat:
- Minimum5mmclearanceismaintainedaroundthe
circumferenceoftheue(airintake).
- Thecombustiblesurfaceandxingsaresuitablefor
supportingtheload.
- Theminimumclearancesfromtheboilercaseare
maintained.
 
 
Theboilerisroomsealedsoapermanentairventisnotrequired.
 
Duetothehighefciencyandlowcasingtemperatureofthis
boiler,cupboardorcompartmentventilationisnotnecessary.
• Existingventilationshouldbeinvestigatedforitspurpose
beforeremoving.